Product Description
The mold is hailed as the "heart" of the ccm, and the mold digital intelligence system can conduct real-time "CT" diagnosis on this "heart", keeping track of the heat transfer status and slag melting conditions of the copper plates in the mold in real time. When abnormalities occur, measures can be taken promptly to prevent steel leakage accidents.
Main Interface for Steel Leakage Forecast
History Interface for Steel Leakage Forecast
3D Temperature Interface for Steel Leakage Forecast
System Function :
Dynamically display the temperature curve of the thermocouple on the copper plate of the mold to help determine steel leakage and predict the quality of the cast billet.
Display the temperature distribution cloud map of the copper plate of the mold, and dynamically monitor the temperature field distribution and heat transfer conditions of the copper plate of the mold.
Dynamically display the average heat flow distribution of the mold, determine the cooling water volume, and prevent the occurrence of cracks in the cast billet.
Dynamically display the changes in the liquid level of the crystallizer, the position of the stopper rods, etc., providing an intuitive understanding of the internal conditions of the crystallizer.
Automatic thermocouple status diagnosis, promptly deactivating abnormal thermocouples and automatically restoring them once the thermocouple temperature value returns to normal.
The system operation information is displayed intuitively and recorded and stored in a timely manner. Operators can view the system detection history at any time.
Steel leakage warning
Typical arrangement of thermocouples